Generate and Enable DECT Serviceability Password
Generates and enables a 16-character DECT serviceability password.
Generating a password and transmitting it to the DECT network can reboot the entire network. Be sure you choose an appropriate time to generate a new password.
The DECT serviceability password, also known as the admin override password, provides read/write access to DECT base stations for performing system serviceability and troubleshooting functions.
This API requires either a full administrator auth token with the scope spark-admin:telephony_config_write
, or a device administrator token with the scope of spark-admin:devices_write
.
URI Parameters
Unique identifier for the location.
Unique identifier for the DECT network.
Query Parameters
Unique identifier for the organization.
Response Properties
16-character serviceability password.
Response Codes
The list below describes the common success and error responses you should expect from the API:
Code | Status | Description |
---|---|---|
200 | OK | Successful request with body content. |
201 | Created | The request has succeeded and has led to the creation of a resource. |
202 | Accepted | The request has been accepted for processing. |
204 | No Content | Successful request without body content. |
400 | Bad Request | The request was invalid or cannot be otherwise served. An accompanying error message will explain further. |
401 | Unauthorized | Authentication credentials were missing or incorrect. |
403 | Forbidden | The request is understood, but it has been refused or access is not allowed. |
404 | Not Found | The URI requested is invalid or the resource requested, such as a user, does not exist. Also returned when the requested format is not supported by the requested method. |
405 | Method Not Allowed | The request was made to a resource using an HTTP request method that is not supported. |
409 | Conflict | The request could not be processed because it conflicts with some established rule of the system. For example, a person may not be added to a room more than once. |
410 | Gone | The requested resource is no longer available. |
415 | Unsupported Media Type | The request was made to a resource without specifying a media type or used a media type that is not supported. |
423 | Locked | The requested resource is temporarily unavailable. A Retry-After header may be present that specifies how many seconds you need to wait before attempting the request again. |
428 | Precondition Required | File(s) cannot be scanned for malware and need to be force downloaded. |
429 | Too Many Requests | Too many requests have been sent in a given amount of time and the request has been rate limited. A Retry-After header should be present that specifies how many seconds you need to wait before a successful request can be made. |
500 | Internal Server Error | Something went wrong on the server. If the issue persists, feel free to contact the Webex Developer Support team. |
502 | Bad Gateway | The server received an invalid response from an upstream server while processing the request. Try again later. |
503 | Service Unavailable | Server is overloaded with requests. Try again later. |
504 | Gateway Timeout | An upstream server failed to respond on time. If your query uses max parameter, please try to reduce it. |
Header
Query Parameters
- orgIdstringUnique identifier for the organization.
{ "password": "?i@9$?F)iR?rHNsu" }